- Install the latest version of Chrome from Chrome's official website.
- Create a new Chrome profile and check "create shortcut on Desktop"
- Go to Chrome Settings and install SecuTix Root Certificate (you can download the certificate from here)
- Extract the zip file you downloaded
- Import the file "SecutixRootCA256.crt" to Chrome "Trusted Root Certification Authorities" via Chrome Settings
![](/download/attachments/49218553/image2017-6-16%2016%3A39%3A27.png?version=1&modificationDate=1549901938000&api=v2)
- Change the "On startup" option to "Open a specific page or set of pages"
- Click on the "Set page" and put in the TVM PoS url that you configured in the previous section "Point of sales configuration"
- Close the Settings menu and go to the page with the TVM PoS url (e.g. https://tvm1-mosa.int1-shop.secutix.com/)
- Right click on the page and click on "Inspect" to open the web inspector
- Go to "Application" tab and input the following <Key, Value> pair into the TVM Web Host's Local Storage:
Key: secutixApiSecretKey
Value: the secret token that's configured in the previous section "Point of sales configuration"
![](/download/attachments/49218553/image2017-6-6%2017%3A12%3A18.png?version=1&modificationDate=1549901938000&api=v2)
- Close Chrome
- Find the Chrome shortcut created at step 2 on desktop & Right click -> Properties
- In the Shortcut > Target field append "--kiosk --disable-pinch --overscroll-history-navigation=0 --remote-debugging-port=9222 --restore-last-session <TVM PoS url that you configured in the previous section>" at the end and Save & Close the properties popup
- Double click the shortcut to start the TVM
- go to the page “pointofsalesurl/content/admin” and check the status. If ticket printer is KO, click on Set ticket counter and input a value. Status should now be ok. Press restart.
- The new TVM is now running in the Kiosk mode on Chrome!
TroubleShooting the TVM
- TVM is not starting on expected page: check point 4/5 and 11. Note that there may be a .bat file that automatically start the TVM. It should be fixed, too.
- Disk full:
- stop the device drivers (there is a stop script in C:\Program Files (x86)\secutix\devicedrivers-manager)
- delete the java folder C:\users\<user>\secutix\java
- reboot
- Accept the startup of the device drivers (select the "remember" option)
- Wait until device driver is started
...
{"serverDuration": 102, "requestCorrelationId": "6f864858e76c1185"}